Pacific Medical 20L Liquid Nitrogen Storage Dewar
Pacific Medical 20L Liquid Nitrogen Storage Dewar
Pacific Medical 20L Liquid Nitrogen Storage Dewar with Ladle and Leather Outer Bag
Features Include
- Made of a high-strength aluminium alloy
- Advanced powder-coated external surface
- Designed for low liquid nitrogen consumption
- 5-year vacuum warranty
- Each unit includes a safety lock lid, neck plug, leather (PU) bag & ladle
Specifications
- Capacity: 20L
- Empty weight: 9.5kg
- Caliber (neck opening of dewar): 50mm
- Outer diameter of dewar: 394mm
- Height of dewar: 672mm
- Static evaporation rate: 0.12L/d
- Static holding time: 168 days
- Ladle outer diameter: 38mm
- Ladle height: 120/276mm
- Number of ladle positions per dewar: 3-6
Straws holding capacity
- Single 120mm (0.5mL): 792pc
- Single 120mm (0.25mL): 1788pc
- Double 276mm (0.5mL): 1284
- Double 276mm (0.25mL): 2832
Liquid Nitrogen Dewar Features
Liquid Nitrogen Dewar Features
Pacific Medical Liquid Nitrogen Storage Dewars.
- Made of a high-strength aluminium alloy.
- Advanced powder coating technology.
- Designed for low liquid nitrogen consumption.
- 5-year vacuum warranty.
- Each unit comes complete with safety lock lid, neck plug, leather (PU) bag & ladle.
- Ergonomic design.
Liquid Nitrogen Dewar Specifications
Liquid Nitrogen Dewar Specifications
Specifications 20L/30L Capacity
- Capacity: 20L/30L
- Weight (empty): 9.5kg/12.9kg
- Neck opening: 50mm
- Outer diameter of dewar: 394mm/462mm
- Height of dewar: 672mm/706mm
- Static evaporation rate: 0.12L/d
- Static holding time: 168 days/254 days
- Ladle outer diameter: 38mm
- Ladle height: 120/276mm
- No. ladles per dewar:3~6
Warranty & Maintenance
Warranty & Maintenance
Warranty
- Our dewars have a 5-year vacuum warranty
The warranty does not apply where
damage is caused by other factors,
including
- Abuse, mishandling, accident or failure to follow operating instructions
- Servicing or modification made by unauthorised parties
- Shipment or other transport damage
Maintenance
It is important to keep your
storage of liquid nitrogen clean. Over time moisture in the Dewar can turn to
slush or ice crystals and lint & foreign material may accumulate and be
transferred into the Cryotherapy flask. Before filling the Dewar every second
time, swill the last 2L of nitrogen around the bottom and empty it outside. Failure to do this may introduce contaminating matter into the Cryotherapy flask
and stop the Regulator or Safety Valve from properly sealing, leading to
leaking or freezing.
External surfaces of the dewar may be cleaned with a neutral detergent & soft lo-lint cloth.
Share